Description
Abbott Lifecare 4100 PCA Plus II
So here you will be able to find the physical, electrical and delivery rate ranges of Abbott Lifecare 4100 PCA Plus II Infusion Pump Repair.
Physical:
- Dimensions: 8″ W x 13″ H x 6″ D
- Weight: 15 lbs.
- Power: 110-120 VAC, 50/60 Hz, 25 W
Delivery Rate Ranges:
Continuous Mode: |
Variable from 0.1x concentration (mg/hr or mcg/hr) to 20.0x concentration (mg/hr or mcg/hr) |
PCA Mode: |
Approximately 1 mL in 35 seconds |
PCA + Continuous Mode: |
Variable from 0.1x concentration (mg/hr or mcg/hr) to 20.0x concentration (mg/hr or mcg/hr) + PCA dose (mg) |
KVO Rate: |
0.1 mL/hr |
Lockout Interval Range: |
5 to 100 minutes in 1-minute increments |
Backpressure Range: |
10 to 20 psig |
Electrical:
- Power Requirements: 110-120 VAC, 50/60 Hz, 25 W
- Power Cord: Hospital-grade AC cord; 10 feet; with transparent plug and retainer
- Fuse: 0.250 A, time lag
- Battery: 8 VDC, four-cell sealed lead-acid, rechargeable battery pack. When fully charged, a battery will typically provide a minimum of 4 hours of operation
Abbott Lifecare 4100 PCA Plus II
Physical:
- Dimensions: 8″ W x 13″ H x 6″ D
- Weight: 15 lbs.
- Power: 110-120 VAC, 50/60 Hz, 25 W
Delivery Rate Ranges:
Continuous Mode: |
Variable from 0.1x concentration (mg/hr or mcg/hr) to 20.0x concentration (mg/hr or mcg/hr) |
PCA Mode: |
Approximately 1 mL in 35 seconds |
PCA + Continuous Mode: |
Variable from 0.1x concentration (mg/hr or mcg/hr) to 20.0x concentration (mg/hr or mcg/hr) + PCA dose (mg) |
KVO Rate: |
0.1 mL/hr |
Lockout Interval Range: |
5 to 100 minutes in 1-minute increments |
Backpressure Range: |
10 to 20 psig |
Electrical:
- Power Requirements: 110-120 VAC, 50/60 Hz, 25 W
- Power Cord: Hospital-grade AC cord; 10 feet; with transparent plug and retainer
- Fuse: 0.250 A, time lag
- Battery: 8 VDC, four-cell sealed lead-acid, rechargeable battery pack. When fully charged, a battery will typically provide a minimum of 4 hours of operation.
Abbott Lifecare 4100 PCA Plus II
Physical:
- Dimensions: 8″ W x 13″ H x 6″ D
- Weight: 15 lbs.
- Power: 110-120 VAC, 50/60 Hz, 25 W
Delivery Rate Ranges:
Continuous Mode: |
Variable from 0.1x concentration (mg/hr or mcg/hr) to 20.0x concentration (mg/hr or mcg/hr) |
PCA Mode: |
Approximately 1 mL in 35 seconds |
PCA + Continuous Mode: |
Variable from 0.1x concentration (mg/hr or mcg/hr) to 20.0x concentration (mg/hr or mcg/hr) + PCA dose (mg) |
KVO Rate: |
0.1 mL/hr |
Lockout Interval Range: |
5 to 100 minutes in 1-minute increments |
Backpressure Range: |
10 to 20 psig |
Electrical:
- Power Requirements: 110-120 VAC, 50/60 Hz, 25 W
- Power Cord: Hospital-grade AC cord; 10 feet; with transparent plug and retainer
- Fuse: 0.250 A, time lag
- Battery: 8 VDC, four-cell sealed lead-acid, rechargeable battery pack. When fully charged, a battery will typically provide a minimum of 4 hours of operation
Related Keyphrase:
- Abbott Lifecare 4100 PCA Plus II Infusion Pump
Download the operator’s Manual
https://web.facebook.com/infusionpumprepair/photos/a.101426038761773/103545561883154