The Abbott LifeCare 4100 PCA Plus II infusion pump system is designed for safe, effective, analgesic delivery to patients through the intravenous or epidural routes in a wide range of clinical settings, including ICU, CCU, SICU, trauma units, bone marrow transplant centers, burn units, oncology centers, and medical/surgical nursing units.

Categories: , , ,

phone Call for price: (855) 477-8866

Download the operator's Manual

Description

Abbott Lifecare 4100 PCA Plus II

So here you will be able to find the physical, electrical and delivery rate ranges of Abbott Lifecare 4100 PCA Plus II Infusion Pump Repair.

Physical:
  • Dimensions: 8″ W x 13″ H x 6″ D
  • Weight: 15 lbs.
  • Power: 110-120 VAC, 50/60 Hz, 25 W
Delivery Rate Ranges:
Continuous Mode: Variable from 0.1x concentration (mg/hr or mcg/hr) to 20.0x concentration (mg/hr or mcg/hr)
PCA Mode: Approximately 1 mL in 35 seconds
PCA + Continuous Mode: Variable from 0.1x concentration (mg/hr or mcg/hr) to 20.0x concentration (mg/hr or mcg/hr) + PCA dose (mg)
KVO Rate: 0.1 mL/hr
Lockout Interval Range: 5 to 100 minutes in 1-minute increments
Backpressure Range: 10 to 20 psig
Electrical:
  • Power Requirements: 110-120 VAC, 50/60 Hz, 25 W
  • Power Cord: Hospital-grade AC cord; 10 feet; with transparent plug and retainer
  • Fuse: 0.250 A, time lag
  • Battery: 8 VDC, four-cell sealed lead-acid, rechargeable battery pack. When fully charged, a battery will typically provide a minimum of 4 hours of operation

Abbott Lifecare 4100 PCA Plus II

Physical:
  • Dimensions: 8″ W x 13″ H x 6″ D
  • Weight: 15 lbs.
  • Power: 110-120 VAC, 50/60 Hz, 25 W
Delivery Rate Ranges:
Continuous Mode: Variable from 0.1x concentration (mg/hr or mcg/hr) to 20.0x concentration (mg/hr or mcg/hr)
PCA Mode: Approximately 1 mL in 35 seconds
PCA + Continuous Mode: Variable from 0.1x concentration (mg/hr or mcg/hr) to 20.0x concentration (mg/hr or mcg/hr) + PCA dose (mg)
KVO Rate: 0.1 mL/hr
Lockout Interval Range: 5 to 100 minutes in 1-minute increments
Backpressure Range: 10 to 20 psig

Electrical:
  • Power Requirements: 110-120 VAC, 50/60 Hz, 25 W
  • Power Cord: Hospital-grade AC cord; 10 feet; with transparent plug and retainer
  • Fuse: 0.250 A, time lag
  • Battery: 8 VDC, four-cell sealed lead-acid, rechargeable battery pack. When fully charged, a battery will typically provide a minimum of 4 hours of operation.

Abbott Lifecare 4100 PCA Plus II

Physical:
  • Dimensions: 8″ W x 13″ H x 6″ D
  • Weight: 15 lbs.
  • Power: 110-120 VAC, 50/60 Hz, 25 W
Delivery Rate Ranges:
Continuous Mode: Variable from 0.1x concentration (mg/hr or mcg/hr) to 20.0x concentration (mg/hr or mcg/hr)
PCA Mode: Approximately 1 mL in 35 seconds
PCA + Continuous Mode: Variable from 0.1x concentration (mg/hr or mcg/hr) to 20.0x concentration (mg/hr or mcg/hr) + PCA dose (mg)
KVO Rate: 0.1 mL/hr
Lockout Interval Range: 5 to 100 minutes in 1-minute increments
Backpressure Range: 10 to 20 psig

Electrical:
  • Power Requirements: 110-120 VAC, 50/60 Hz, 25 W
  • Power Cord: Hospital-grade AC cord; 10 feet; with transparent plug and retainer
  • Fuse: 0.250 A, time lag
  • Battery: 8 VDC, four-cell sealed lead-acid, rechargeable battery pack. When fully charged, a battery will typically provide a minimum of 4 hours of operation