- Abbott Lifecare PCA 3 -

Abbott Lifecare PCA 3

Abbott Lifecare PCA 3

The LifeCare PCA 3 Infusion System is the most advanced PCA device to help address wrong dose and wrong drug errors. The LifeCare PCA 3 uses an integrated approach to patient-controlled analgesia and helps to enhance patient safety and efficiency through bar code technology and advanced software design. Pre-Filled bar-coded drug syringes provide quality and enhanced safety.

Features
  • Designed to help reduce medication errors, enhance utility and increase efficiency.
  • Built-in bar code reader automatically identifies drug name and drug concentration.
  • Review screens confirm data input before infusion begins.
  • Advanced software, soft-function keys and numeric keypad Stored speed protocol function saves time and increases compliance with standing orders.
  • Designed to help reduce medication errors, enhance utility and increase efficiency.
  • Built-in bar code reader automatically identifies drug name and drug concentration.
  • Review screens confirm data input before infusion begins.
  • Advanced software, soft-function keys and numeric keypad Stored speed protocol function saves time and increases compliance with standing orders.
Categories: , ,

phone Call for price: (855) 477-8866

Download the operator's Manual

Description

Abbott Lifecare PCA 3

So here you will be able to find the physical, electrical, environment, occlusion and alarms of Abbott Lifecare PCA 3 Infusion Pump Repair.

PHYSICAL
  • Dimensions: Approximately 8 W x 13 H x 6 D in. (excluding pole clamp, power cord)
  • Weight: Approximately 10 lbs. with battery
  • Casing: High-impact plastic
ELECTRICAL
  • Power Requirements: 105-130 V, 57 – 63 Hz, 50 W
  • Power Cord: Hospital-grade AC cord. 10 feet with transparent plug and retainer plate
  • Fuses: 0.5 A, 250 V, Slo-Blo
  • Battery: One sealed lead acid, rechargeable 8 V battery, internal to the device
  • Battery Operation: A fully charged new battery provides four hours of operation and delivers 30 mL of solution. Operation time is measured from initial pumping to the LOW BATTERY alarm.
  • Recharge: The battery charges whenever the infusion pump is connected to AC power. After a LOW BATTERY alarm, the battery will recharge to 80% of full capacity within 16 hours.
  • Self-Discharge: A fully charged battery will retain a minimum 20% of the initial charge for six months when the infusion pump is not connected to AC power or is not operating, and is stored at 20° C.
ENVIRONMENT
  • Operating: 41° to 104° F (5° to 40° C) 10% to 90% relative humidity
  • Transporting and Storage: -4° to 140° F (-20° to 60° C) 10% to 90% relative humidity
  • Atmospheric Pressure: 0 – 10,000 feet (0 – 3000 meters) or equivalent atmospheric pressure
  • Relative Humidity: 10 – 90% non-condensing up to 104° F (40° C); maximum of 15% non-condensing above 104° F (40° C)
OCCLUSION ALARM AND LIMITS
  • Backpressure Range: 10 to 20 psi
  • MODES
  • PCA Only: Approximately 1 mL in 35 seconds
  • Continuous Only: Variable from 0.1 – 20x concentration (mg/hr or mcg/hr)
  • PCA + Continuous: Variable from 0.1 – 20x concentration (mg/hr or mcg/hr)
  • Lockout Interval Range: 5 to 120 minutes in one minute increments

Abbott Lifecare PCA 3

PHYSICAL

Dimensions: Approximately 8 W x 13 H x 6 D in. (excluding pole clamp, power cord)

Weight: Approximately 10 lbs. with battery

Casing: High-impact plastic

ELECTRICAL

Power Requirements: 105-130 V, 57 – 63 Hz, 50 W

Power Cord: Hospital-grade AC cord. 10 feet with transparent plug and retainer plate

Fuses: 0.5 A, 250 V, Slo-Blo

Battery: One sealed lead acid, rechargeable 8 V battery, internal to the device

Battery Operation: A fully charged new battery provides four hours of operation and delivers 30 mL of solution. Operation time is measured from initial pumping to the LOW BATTERY alarm.

Recharge: The battery charges whenever the infusion pump is connected to AC power. After a LOW BATTERY alarm, the battery will recharge to 80% of full capacity within 16 hours.

Self-Discharge: A fully charged battery will retain a minimum 20% of the initial charge for six months when the infusion pump is not connected to AC power or is not operating, and is stored at 20° C.

ENVIRONMENT

Operating: 41° to 104° F (5° to 40° C) 10% to 90% relative humidity

Transporting and Storage: -4° to 140° F (-20° to 60° C) 10% to 90% relative humidity

Atmospheric Pressure: 0 – 10,000 feet (0 – 3000 meters) or equivalent atmospheric pressure

Relative Humidity: 10 – 90% non-condensing up to 104° F (40° C); maximum of 15% non-condensing above 104° F (40° C)

OCCLUSION ALARM AND LIMITS

Backpressure Range: 10 to 20 psi

MODES

PCA Only: Approximately 1 mL in 35 seconds

Continuous Only: Variable from 0.1 – 20x concentration (mg/hr or mcg/hr)

PCA + Continuous: Variable from 0.1 – 20x concentration (mg/hr or mcg/hr)

Lockout Interval Range: 5 to 120 minutes in one minute increments

Download the operator’s Manual

https://web.facebook.com/infusionpumprepair/photos/a.101426038761773/103537081884002

Related Keyphrase:

  • Abbott Lifecare PCA 3 Infusion Pump