- B Braun Horizon NXT -

B Braun Horizon NXT

B Braun Horizon NXT

The Horizon NXT is intended for use with B. Braun McGaw Horizon I.V. sets to regulate the flow of primary and secondary fluids when positive pressure is required. The infusion system is capable of delivering fluid from a negative head height (when the I.V. fluid container is lower than the pump), and provides clinically accepted volumetric accuracy for all standard I.V. fluids, including blood, lipids and TPN.

Features
  • Primary and Piggyback Modes
  • Dose Mode (dose rate calculator) with customizable drug menus
  • q(x)º Mode for intermittent therapies
  • Program Mode for variable delivery regimens
  • Profile Mode for TPN and other ramped and tapered infusions
  • Set Time and Volume to calculate infusion rate
  • Micro Mode for limiting infusion rates of high risk/high concentration drugs
Categories: , ,

phone Call for price: (855) 477-8866

Download the operator's Manual

Description

B Braun Horizon NXT

So here you will be able to find the mechanism, width, height, depth, weight and power of B Braun Horizon NXT Infusion Pump Repair.

  • Mechanism: Volumetric, Positive Pressure Displacement Reservoir
  • Width: 31.5 cm (12.4 in)
  • Height: 12.2 cm (4.8 in)
  • Depth: 31.5 cm (12.2 in)
  • Weight: 5.4 kg (11.9 lbs)
  • Power: 90-132 VAC, 30 Watts, 47/63 Hz USA excluding accessories
  • Grounding Resistance: Meets UL Standard 544
  • Leakage Current: Meets or exceeds UL Standard 544,Section 27.2 and ANSI/AAMI SafeCurrent Limits (7/9/85)
  • Battery: 12 V sealed lead-acid battery forambulatory use
  • Battery Operating Time: 4 hours at 125 ml/hr
  • Rate Range: 0.1 to 999.9 ml/hr in 0.1 increments
  • Volume to be Infused Range: 0.1 to 9999.9 ml
  • Variable Occlusion Pressure: 75, 100, 200, 300, 400, 500, and 750mmHg
  • KVO Rate: 3 ml/hr or selected rate, whichever is lower
  • Accuracy: Volume Delivered 5%
  • Alarms: Air-in-line, Container Empty, Door Open,Downstream Occlusion, Hold TimeExceeded, Low Battery, Low Flow fromContainer, System Error, UpstreamOcclusion, Set Improperly Loaded
  • Memory: Permanent data retention after the pump isturned off unless alternative Data RetentionDefaults have been selected in the BiomedOptions
  • Tubing: Horizon cassette tubing
  • Compatible Syringes: 3-60 ml any manufacturer
  • Modes/Features: Dose Mode with Drug Menu, Primary andPiggyback Modes, Set Time and Volume,Schedule Next Run, Profile Mode forTPN, Program Mode, q(x)º Mode, SiteTrend, Variable Occlusion Pressure,Micro Mode

B Braun Horizon NXT

  • Mechanism: Volumetric, Positive PresssureDisplacement Reservoir
  • Width: 31.5 cm (12.4 in)
  • Height: 12.2 cm (4.8 in)
  • Depth: 31.5 cm (12.2 in)
  • Weight: 5.4 kg (11.9 lbs)
  • Power: 90-132 VAC, 30 Watts, 47/63 Hz USAexcluding accessories
  • Grounding Resistance: Meets UL Standard 544
  • Leakage Current: Meets or exceeds UL Standard 544,Section 27.2 and ANSI/AAMI SafeCurrent Limits (7/9/85)
  • Battery: 12 V sealed lead-acid battery forambulatory use
  • Battery Operating Time: 4 hours at 125 ml/hr
  • Rate Range: 0.1 to 999.9 ml/hr in 0.1 increments
  • Volume to be Infused Range: 0.1 to 9999.9 ml
  • Variable Occlusion Pressure: 75, 100, 200, 300, 400, 500, and 750mmHg
  • KVO Rate: 3 ml/hr or selected rate, whichever is lower
  • Accuracy: Volume Delivered 5%
  • Alarms: Air-in-line, Container Empty, Door Open,Downstream Occlusion, Hold TimeExceeded, Low Battery, Low Flow fromContainer, System Error, UpstreamOcclusion, Set Improperly Loaded
  • Memory: Permanent data retention after the pump isturned off unless alternative Data RetentionDefaults have been selected in the BiomedOptions
  • Tubing: Horizon cassette tubing
  • Compatible Syringes: 3-60 ml any manufacturer
  • Modes/Features: Dose Mode with Drug Menu, Primary andPiggyback Modes, Set Time and Volume,Schedule Next Run, Profile Mode forTPN, Program Mode, q(x)º Mode, SiteTrend, Variable Occlusion Pressure,Micro Mode

Related Keyphrase:

  •  B Braun Horizon NXT Infusion Pump

Download the operator’s Manual