B Braun Outlook 100

B Braun Outlook 100

The Outlook™ 100 is intended for use with B. Braun Medical Inc. Horizon® Pump IV Sets to regulate the flow of primary and secondary fluids when positive pressure is required. The infusion system is capable of delivering fluid from a negative head height (when the IV fluid container is lower than the pump), and provides clinically accepted volumetric accuracy for all standard IV fluids, including blood, lipids, and Total Parenteral Nutrition (TPN).

Positive pressure is frequently a necessity, but clinical experience shows that high pressure limits may increase the severity of an infiltration without causing an alarm. Because there is a need to control pump pressure settings, the Outlook ES has user-selectable Occlusion Limit settings which start at 75 mmHg and extend to 750 mmHg.

The pump is equipped with distinct audible and visual alarm signals to indicate Keep Vein Open (KVO), low battery, and other alarm conditions.

Features
  • Promotes patient safety by helping to avoid accidental under- or overdosing using audible
  • and visual alerts
  • Provides flexibility for each care area—ability to customize dose limits to your hospital drug formulary
  • Promotes clinician choice with dose limit override when limits are exceeded during manual programming and titration
  • Visually indicates dose selection with DoseGuard™ software
  • Easy to learn:

– Manual operation RATE, VOLUME, RUN

– Automatic Dose Rate Calculator

– Large, highly visible keys

  • Reduce nuisance air-in-line alarms with air-trapping cassette
  • Stackable modular design reduces bedside cord clutter and errors due to channel confusion
  • Comprehensive line of needle-free administration sets including UV light resistant tubing that protects drug efficacy
Categories: , ,

phone Call for price: (855) 477-8866

Download the operator's Manual

Description

B Braun Outlook 100

Here are some features of B Braun Outlook 100 Infusion Pump Repair and b braun outlook 100 service manual.

  • Mechanism: Volumetric, Positive Pressure Displacement Reservoir
  • Dimensions: 12” W x 4.5” H x 8.75” D
  • Weight: 11 lbs
  • Power: 120 VAC, 3A, 60 Hz USA excluding accessories
  • Grounding Resistance: Meets UL Standard 2601-1
  • Leakage current: Meets or Exceeds UL Standard 2601-1
  • Battery: 12 V sealed lead-acid battery
  • Battery Operating Time: 3 hours at 125 mL/hr
  • Rate Range: 0.1 to 999.9 mL/hr in 0.1 mL increments
    • Micro Mode: 0.1 to 99.9 mL/hr in 0.1 mL increments
  • Volume to be Infused Range: 0.1 to 9999.9 mL in 0.1 mL increments
  • KVO Rate: 3 mL/hr or selected rate, whichever is lower
  • Volumetric Accuracy: ± 5%
  • Alarms: Air-in-Line, Bag Empty, Door Open, Downstream Occlusion, Hold time Exceeded, Low Battery, Plug-in, System Error, Upstream Occlusion, Check Set, DoseGuard™ Alert
  • Memory: Permanent data retention after the pump is turned off unless alternative Data Retention Defaults have been selected in the Biomed Options.
  • Tubing: Horizon® Pump Sets
  • Modes/Features: Dose Mode with Drug Menu and DoseGuard™ dose limits, Primary and Piggyback Modes, Set Time and Volume, Schedule Next Run, Profile Mode for TPN, Program Mode, q(x) Mode, Site Trend, Variable Occlusion Pressure, Micro Mode, Epidural Mode

B Braun Outlook 100

  • Mechanism: Volumetric, Positive Pressure Displacement Reservoir
  • Dimensions: 12” W x 4.5” H x 8.75” D
  • Weight: 11 lbs
  • Power: 120 VAC, 3A, 60 Hz USA excluding accessories
  • Grounding Resistance: Meets UL Standard 2601-1
  • Leakage current: Meets or Exceeds UL Standard 2601-1
  • Battery: 12 V sealed lead-acid battery
  • Battery Operating Time: 3 hours at 125 mL/hr
  • Rate Range: 0.1 to 999.9 mL/hr in 0.1 mL increments
    • Micro Mode: 0.1 to 99.9 mL/hr in 0.1 mL increments
  • Volume to be Infused Range: 0.1 to 9999.9 mL in 0.1 mL increments
  • KVO Rate: 3 mL/hr or selected rate, whichever is lower
  • Volumetric Accuracy: ± 5%
  • Alarms: Air-in-Line, Bag Empty, Door Open, Downstream Occlusion, Hold time Exceeded, Low Battery, Plug-in, System Error, Upstream Occlusion, Check Set, DoseGuard™ Alert
  • Tubing: Horizon® Pump Sets
  • Modes/Features: Dose Mode with Drug Menu and DoseGuard™ dose limits, Primary and Piggyback Modes, Set Time and Volume, Schedule Next Run, Profile Mode for TPN, Program Mode, q(x) Mode, Site Trend, Variable Occlusion Pressure, Micro Mode, Epidural Mode

Related Keyphrase:

  • B Braun Outlook 100 Infusion Pump
  • b braun outlook 100 service manual

Download the operator’s Manual