The B Braun Perfusor basic is a microprocessor controlled, portable syringe pump designed to deliver intermittent infusions. The syringe sizes used are 3cc to 10cc, and delivery times range from 10 to 60 minutes. When the time has been set and the syringe is in place, the pump automatically calculates the proper speed and occlusion pressure.

Categories: ,

phone Call for price: (855) 477-8866

Download the operator's Manual

Description

B Braun Perfusor Basic

So here you will be able to find the specifications B Braun Perfusor Basic Infusion Pump Repair and the b braun perfusor basic service manual. Here are the dimensions, weight, syringes, rate parameter and etc. Download b braun perfusor basic service manual

  • Dimensions: 9.75” H x 2.75” W x 5” D
  • Weight: 2 lbs
  • Syringes: BD Plastipak™ 3cc to 60cc
  • Rate Parameters: 1.5 mL/hr (3cc syringe) to 360 mL/hr (60cc syringe)
  • Delivery Time: 10 – 60 min., in 2.5 min. increments
  • Battery: Requires 4 C-size alkaline batteries
  • Battery Life: 400 hours typical, 10 hours on Low Battery
  • Accuracy: ± 3%
  • Displays:
    • LED: Infuse, Attention, Low Battery, Infusion Complete.
    • LCD: Time Remaining, Original Set Time; some revisions have Infusion complete indicator.
  • Occlusion Limits (using BD Plastipak™ syringes):
Syringe

Size

Maximum Occlusion

Pressure (psi)

Typical Occlusion

Pressure (psi)

3 cc 46.8 36.4
5 cc 30.0 17.9
10 cc 22.8 17.0
20 cc 21.6 13.9
30 cc 16.8 9.4
60 cc 13.2 8.4

B Braun Perfusor Basic

Download b braun perfusor basic service manual

  • Dimensions: 9.75” H x 2.75” W x 5” D
  • Weight: 2 lbs
  • Syringes: BD Plastipak™ 3cc to 60cc
  • Rate Parameters: 1.5 mL/hr (3cc syringe) to 360 mL/hr (60cc syringe)
  • Delivery Time: 10 – 60 min., in 2.5 min. increments
  • Battery: Requires 4 C-size alkaline batteries
  • Battery Life: 400 hours typical, 10 hours on Low Battery
  • Accuracy: ± 3%
  • Displays:
    • LED: Infuse, Attention, Low Battery, Infusion Complete.
    • LCD: Time Remaining, Original Set Time; some revisions have Infusion complete indicator.
  • Occlusion Limits (using BD Plastipak™ syringes):
Syringe

Size

Maximum Occlusion

Pressure (psi)

Typical Occlusion

Pressure (psi)

3 cc 46.8 36.4
5 cc 30.0 17.9
10 cc 22.8 17.0
20 cc 21.6 13.9
30 cc 16.8 9.4
60 cc 13.2 8.4

 