- Baxter Flo-Gard 6201 -

Baxter Flo-Gard 6201

Baxter Flo-Gard 6201

The Baxter Flo-Gard 6201 volumetric infusion pump is the industry standard in standard set infusion pump technology. It can deliver a wide variety of fluids over a broad range of infusion rates.

Features

Enhanced Safety

  • Flow Check Occlusion Alarm – An in-line resistance display of incremental back pressure.
  • Flow Rate Calculation is automatic after volume and time are selected.
  • Slide Clamp Option offers an additional step to protect against inadvertent gravity free flow.
  • Front Panel Lock-out protects against tampering.

Greater Convenience and Versatility

  • Programmed Delivery Profile allows up to 10 steps, individualizing control of infusion ramping and tapering.
  • Incremental Flow Rate can deliver 1-99.9 mL /hr in increments of 0.1 ml/hr.
  • Automatic Restart once occlusion clears.
  • Automatic Piggybacking of secondary medications.

Cost-Efficiency

  • Uses Baxter standard administration sets.
  • Eliminates the need for costly disposable sets.
  • Reduces potential for waste.

phone Call for price: (855) 477-8866

Download the operator's Manual

Description

Baxter Flo-Gard 6201

So here you will be able to find the dimensions, weight, power, flow rate range and  KVO rate of this Infusion Pump Repair. Download baxter flo gard 6201 common failure f 49 and baxter flo gard 6201 battery

  • Dimensions: 9.5W x 11.4H x 5.1D in.
  • Weight: 11.6 lb.
  • Power: 110/120V, 60 Hz.
  • Flow Rate Range (Primary program): 1.0-99.9 mL/hr in 0.1 mL increments or 1-1999 mL/hr in 1ml increments.
  • Flow Rate Range (Secondary program): 1.0-99.9 mL/hr in 0.1 mL increments or 1-999 mL/hr in 1mL increments.
  • KVO Rate: 5 mL/hr or programmed rate, whichever is less.
  • Ramp PDP Parameter Ranges: Total VTBI: 100-9,999 in 1 mL increments. Upper limit can be reduced by authorized service personnel.
  • Delay Time: 00:00 – 08:00 hours in minute increments.
  • Run Time: 01:00 – 16:00 hours in minute increments.
  • Ramp Up: 00:00 to 45% of the Run Time, in minute increments.
  • Ramp Down: 00-00 to the Run Time minus Ramp Up, in minute Increments.
  • VTBI Range: 1.0-99.9 mL in 0.1 mL increments or 1-9999 mL in 1 mL increments for both primary and secondary.

Baxter Flo-Gard 6201

Download 6201 common failure f 49 and Baxter flo gard 6201 battery

baxter 6201 infusion pump

Dimensions: 9.5W x 11.4H x 5.1D in.

Weight: 11.6 lb.

Power: 110/120V, 60 Hz.

Flow Rate Range (Primary program): 1.0-99.9 mL/hr in 0.1 mL increments or 1-1999 mL/hr in 1ml increments.

Flow Rate Range (Secondary program): 1.0-99.9 mL/hr in 0.1 mL increments or 1-999 mL/hr in 1mL increments.

KVO Rate: 5 mL/hr or programmed rate, whichever is less.

Ramp PDP Parameter Ranges: Total VTBI: 100-9,999 in 1 mL increments. Upper limit can be reduced by authorized service personnel.

Delay Time: 00:00 – 08:00 hours in minute increments.

Run Time: 01:00 – 16:00 hours in minute increments.

Ramp Up: 00:00 to 45% of the Run Time, in minute increments.

Ramp Down: 00-00 to the Run Time minus Ramp Up, in minute Increments.

VTBI Range: 1.0-99.9 mL in 0.1 mL increments or 1-9999 mL in 1 mL increments for both primary and secondary.