- Alaris Signature 7130 -

Alaris Signature 7130

Alaris Signature 7130

The Alaris IVAC Signature Gold 7130 Infusion Pump is a single channel volumetric infusion pump that allows independent programming on both sides. It can be used for general IV infusions, antibiotics, blood infusions, enteral infusions, TPN and hyperalimentation, and lipids. Monitoring options provide increased awareness of occlusion detection and battery charge condition. Dual-rate piggyback function and panel lock.

A multi-step program function allows a sequential program to deliver up to nine rates and volumes; can also be programmed using volume and time. Multiple infusions can be pre-programmed over a period of up to 24 hours; delay start and loading dose features. Computer interface for remote monitoring. Rotating pole clamp for pole or bed-rail mounting. Drug-specific dose rates can be calculated by selecting a drug name, which will then display on the screen. Recommended for epidural infusions. Optional flow sensor.

phone Call for price: (855) 477-8866

Download the operator's Manual

Description

Alaris Signature 7130

So here you will be able to find the specifications of  Alaris Signature 7130 Infusion Pump Repair. Here are the dimensions, weight, power cord, battery, operating conditions, case,  power requirement and etc.

  • Dimensions: 7.7” W x 8.6” H x 5.0” D (without power cord)
  • Weight: 6.85 lbs./3.11 kg (without pole clamp)
  • Power Cord: 10 ft
  • Case: Impact and flame resistant plastic
  • Power Requirements: 100-120 V~,50/60 Hz, 0.5 A, 3-wire grounded system (40 watts Max)
  • Battery: Rechargeable nickel cadmium. With a new, fully charged battery, the pump will operate for 4 hours nominal.
  • Operating Conditions: 50-104° F and 20-90% humidity, non-condensing
  • Storage Conditions: -40 – 140° F and 5-95% humidity, non-condensing
  • Ground Current Leakage: Tested to UL 544 and CSA C22.2 No. 125 for medical and dental equipment.
  • Mode of Operation: Continuous
  • KVO Flow Range: 0.1 – 20.0 ml/hr in 0.1 ml/hr increments
  • Flow Rate Range:
  • 1 to 999.9 ml/hr in 0.1 ml/hr increments (primary)
  • 1 to 270.0 ml/hr in 0.1 ml/hr increments (secondary)
  • Flow Rate Accuracy: ±5% at 1.0 – 999.9 ml/hr; ±6.5% at 0 – 1.0 ml/hr
  • Volume To Be Infused Range:
  • 1 to 9999.9 ml in 0.1 ml increments (primary and dose rate modes)
  • 1 to 999.9 ml in 0.1 ml increments (secondary)
  • Volume Infused Range:
  • 0 to 9999.9 ml in 0.1 ml increments

Alarms

  • Accumulated Air in Line
  • Air in Line
  • Battery Depleted
  • Channel Malfunction
  • Computer Link Failure
  • Flow Sensor Unplugged
  • Hold Time Exceeded
  • Instrument Malfunction
  • Key stuck
  • Latch Open
  • No Upstream Flow Detected
  • Occlusion Downstream
  • Occlusion Upstream
  • Primary Flow Detected during Secondary
  • Set Out
  • Set Up Time Exceeded

Alaris Signature 7130

  • Dimensions: 7.7” W x 8.6” H x 5.0” D (without power cord)
  • Weight: 6.85 lbs./3.11 kg (without pole clamp)
  • Power Cord: 10 ft
  • Case: Impact and flame resistant plastic
  • Power Requirements: 100-120 V~,50/60 Hz, 0.5 A, 3-wire grounded system (40 watts Max)
  • Battery: Rechargeable nickel cadmium. With a new, fully charged battery, the pump will operate for 4 hours nominal.
  • Operating Conditions: 50-104° F and 20-90% humidity, non-condensing
  • Storage Conditions: -40 – 140° F and 5-95% humidity, non-condensing
  • Ground Current Leakage: Tested to UL 544 and CSA C22.2 No. 125 for medical and dental equipment.
  • Mode of Operation: Continuous
  • KVO Flow Range: 0.1 – 20.0 ml/hr in 0.1 ml/hr increments
  • Flow Rate Range:
  • 1 to 999.9 ml/hr in 0.1 ml/hr increments (primary)
  • 1 to 270.0 ml/hr in 0.1 ml/hr increments (secondary)
  • Flow Rate Accuracy: ±5% at 1.0 – 999.9 ml/hr; ±6.5% at 0 – 1.0 ml/hr
  • Volume To Be Infused Range:
  • 1 to 9999.9 ml in 0.1 ml increments (primary and dose rate modes)
  • 1 to 999.9 ml in 0.1 ml increments (secondary)
  • Volume Infused Range:
  • 0 to 9999.9 ml in 0.1 ml increments

Alarms

  • Accumulated Air in Line
  • Air in Line
  • Battery Depleted
  • Channel Malfunction
  • Computer Link Failure
  • Flow Sensor Unplugged
  • Hold Time Exceeded
  • Instrument Malfunction
  • Key stuck
  • Latch Open
  • No Upstream Flow Detected
  • Occlusion Downstream
  • Occlusion Upstream
  • Primary Flow Detected during Secondary
  • Set Out
  • Set Up Time Exceeded

Related Keyphrase:

  • Alaris 7130 Pump Repair
  • Alaris Signature Infusion Pump
  • 7130 Pump Infusion

Download the operator’s Manual

https://web.facebook.com/infusionpumprepair/photos/a.101426038761773/102081762029534