- CME BodyGuard 121 Twins -

CME BodyGuard 121 Twins

CME BodyGuard 121 Twins

Manage two regimens for your patient, bedside or on the go, using
the BodyGuard 121 Twins™ dual-channel infusion pump from CME.
Priced to compete with larger devices, the BodyGuard 121 Twins™
pump gives you the flexibility to deliver antibiotic, chemotherapy,
TPN, and PCA infusion. Lightweight, easy-to-use design lets you set
it up anywhere your patient needs care.

Features

2 Independent Infusion Channels

Deliver 2 separate treatment regimens using one keypad.

​Piston Mechanism

Delivers ± 5 % accuracy and 1.8μl linear infusion even at the low flow rates.

BodyComm™ Software

Review patient history with charts and up to 1000 events log or manage pump settings on your PC.

EMR Ready

Connect to Electronic Medical Record systems to increase safety and optimize clinical workflow.

 

Categories: , ,

phone Call for price: (855) 477-8866

Download the operator's Manual

Description

CME BodyGuard 121 Twins

So here you will be able to find the flow rate, accuracy, volume, KVO rate, pressure, air and pump system of CME BodyGuard 121 Twins Infusion Pump Repair.

  • Flow rate: 0.1 – 1,200 ml/h; 0.0 – 100 ml/h in PCA mode
  • Accuracy: +/- 5%
  • Volume: 0.1 – 9,999.0 ml
  • KVO rate: 0.1 – 5.0 ml/h
  • Pressure: max. 990 mmHg or 19.9 psi adjustable
  • Air: ultrasound sensor, threshold value 0.1 -1.0 ml
  • Pump system: piston mechanism
  • Alarms: end program; battery low; battery empty; air in line; occlusion; door open; pump locked; lock mode; pump unattended; error; check set
  • Power supply: 110 – 240 V; 50/60 Hz; 0.3 A max.
  • Battery: Li-Ion; 3,000 mAh
  • Size: 89 x 149 x 41 mm (W x L x H)
  • Weight: 280 g (without battery), 580 g (with battery)

CME BodyGuard 121 Twins

  • Flow rate: 0.1 – 1,200 ml/h; 0.0 – 100 ml/h in PCA mode
  • Accuracy: +/- 5%
  • Volume: 0.1 – 9,999.0 ml
  • KVO rate: 0.1 – 5.0 ml/h
  • Pressure: max. 990 mmHg or 19.9 psi adjustable
  • Air: ultrasound sensor, threshold value 0.1 -1.0 ml
  • Pump system: piston mechanism
  • Alarms: end program; battery low; battery empty; air in line; occlusion; door open; pump locked; lock mode; pump unattended; error; check set
  • Power supply: 110 – 240 V; 50/60 Hz; 0.3 A max.
  • Battery: Li-Ion; 3,000 mAh
  • Size: 89 x 149 x 41 mm (W x L x H)
  • Weight: 280 g (without battery), 580 g (with battery)
  • Flow rate: 0.1 – 1,200 ml/h; 0.0 – 100 ml/h in PCA mode
  • Accuracy: +/- 5%
  • Volume: 0.1 – 9,999.0 ml
  • KVO rate: 0.1 – 5.0 ml/h
  • Pressure: max. 990 mmHg or 19.9 psi adjustable
  • Air: ultrasound sensor, threshold value 0.1 -1.0 ml
  • Pump system: piston mechanism
  • Alarms: end program; battery low; battery empty; air in line; occlusion; door open; pump locked; lock mode; pump unattended; error; check set
  • Power supply: 110 – 240 V; 50/60 Hz; 0.3 A max.
  • Battery: Li-Ion; 3,000 mAh
  • Size: 89 x 149 x 41 mm (W x L x H)
  • Weight: 280 g (without battery), 580 g (with battery)