- Excelsior ESP -

Excelsior ESP

Excelsior ESP

The ESP Syringe Pump is a small, compact infusion pump, which infuses doses with 3cc-60cc syringes. It has a plastic case, syringe clamp, pusher block and membrane type keypad. The pump is user friendly – all user information is displayed on the pump’s front. Three speeds provide versatility to extend delivery time by a factor of 2 or 3. Only one button to start infusion, no drip counting, activation, spiking or admixture. The pump provides visual and audible alarms for end of infusion, occlusion, low battery, accuracy and system malfunction.

The Excelsior ESP Syringe Pump is similar in appearance and operation to the Baxter 300XL. Like the 300XL, it features 3 motor speeds, allows the clinician to set the time of delivery, and accepts most syringe sizes. Using the plug­-in adapter the pump can also infuse solutions from 140 ml syringes which are available from Excelsior or Monoject. The adapter contains electronic components inside the plastic piece which supplement the internal pump motor electronics and allow the larger infusion; an extra­large syringe clamp will accept syringes of 3ml. up to 140 ml. in size. The time of infusion is also longer than the Baxter 300XL’s; in the Xslow mode, infusion time can be as long as 150 minutes.

phone Call for price: (855) 477-8866

Download the operator's Manual

Description

Excelsior ESP

Here are some features of Excelsior ESP Infusion Pump Repair.

  • Accepts one-­handed disposable syringes from 3ml – 140ml; One button to start infusion; All user information is displayed on front of unit
  • No pump programming needed
  • No drip counting, activation, spiking or admixture needed
  • Self-­calibration is automatic – Continuously monitors speed of motor up to 670 times per second to ensure travel accuracy of ± 3%
  • 3 speeds provide versatility to extend delivery time by a factor of 2 or 3
  • Visual and Audible Alarms for end of infusion, occlusion, low battery, accuracy and system malfunction; Audible alarm may be turned off during infusion
  • Durable – Proven Reliability: Heavy-­duty mechanism withstands extreme usage
  • Membrane keypad is easily cleaned and prevents fluid from entering the pump
  • Small Ergonomic Design: Four C­Cell batters provide up to 400 hours of use
  • UL Classified
  • U.S. Manufactured
Rate Parameters:  5.2 – 77.5 ml/hr
Time Parameters:  10-150 minutes
Syringe Sizes:  Monoject, Terumo, BD, or Excelsior, from 3ml – 140ml
Occlusion Limits:  9.2 – 45 PSI, depending on syringe
Batteries: Four size “C” cells
Battery Life: Approximately 400 hours typical
Accuracy: ±3%
Size: 9.2” x 1.7” x 4.7”
Weight: 1.2 lbs., not including batteries

Excelsior ESP

  • Accepts one-­handed disposable syringes from 3ml – 140ml; One button to start infusion; All user information is displayed on front of unit
  • No pump programming needed
  • No drip counting, activation, spiking or admixture needed
  • Self-­calibration is automatic – Continuously monitors speed of motor up to 670 times per second to ensure travel accuracy of ± 3%
  • 3 speeds provide versatility to extend delivery time by a factor of 2 or 3
  • Visual and Audible Alarms for end of infusion, occlusion, low battery, accuracy and system malfunction; Audible alarm may be turned off during infusion
  • Durable – Proven Reliability: Heavy-­duty mechanism withstands extreme usage
  • Membrane keypad is easily cleaned and prevents fluid from entering the pump
  • Small Ergonomic Design: Four C­Cell batters provide up to 400 hours of use
  • UL Classified
  • U.S. Manufactured

Related Keyphrase:

  • Excelsior ESP Infusion Pump

Download the operator’s Manual

https://web.facebook.com/infusionpumprepair/photos/a.101426038761773/102817985289245