- Hospira Plum 360 -

Hospira Plum 360

Hospira Plum 360

The ICU Medical Hospira Plum 360 infusion pump was designed with safety and efficiency in mind. The Plum 360 features a unique closed air management system that allows for automated back-priming to easily remove air from the line without disconnecting from the patient. This large volume IV pump allows a secondary line that connects directly to the cassette. The Plum pump will alert you if the secondary line is not infusing. It has a lot of features that are designed to help you enhance patient safety and increase clinical efficiency.

The Plum 360 can act as a standalone infuser or in conjunction with ICU Medical MedNet software to provide medication safety software at the point of care, with customized drug libraries to support hospital defined protocols by clinical care areas. The Plum pump can communicate with systems on the network via Ethernet or wireless communication using an 802.11 a/b/g/n dual-band radio. The Plum 360 infuser is fully compatible with Plum Series administration sets and accessories, and the CLAVE needleless connection systems, providing a convenient and cost-effective infusion system.

The Plum 360 infusion system is primarily used in parenteral, enteral, and epidural therapies and the administration of whole blood and blood products. It’s used in clinical environments at the direction of licensed physicians or certified healthcare professionals.

  • Bolus delivery capability to facilitate rapid infusion.
  • Intregrated free-flow protection in the PlumSet cassette technology.
  • Automated concurrent and piggyback delivery.
  • Capability of full IV-EHR interoperability.
  • Connects secondary line directly to the PlumSet cassette.
Categories: , ,

phone Call for price: (855) 477-8866

Download the operator's Manual

Description

Hospira Plum 360

Here are the specifications of  Hospira Plum 360 Infusion Pump Repair. Download hospira plum 360 price

Dimensions
  • Height: 8” (20 cm)
  • Width: 8” (20 cm)
  • Depth: 6” (15 cm)
  • Weight: 10 lbs (4.5 kg)
Battery
  • Type: Sealed lead-acid rechargeable 6V internal battery.
  • Operating Time: About 7 hours when infusing at 25mL/hr and 4 hours at 999 mL/hr.
  • Recharge Time: Up to 8 hours with device operating at 125 mL/hr on one line.
VTBI Range
  • 0.1 to 99.9 mL (in 0.1 mL increments)
  • 100 to 9999 mL (in 1 mL increments)
Delivery Rate Range and Duration
  • Lines A and B: 0.1 to 99.9 mL/hr (in 0.1 mL increments)
  • 100 to 999 mL/hr (in 1 mL increments)
  • Concurrent Delivery: 0.5 mL/hr minimum for each line
  • PlumSet: 500 mL/hr cumulative (A+B) maximum
  • KVO: 1.0 mL/hr or the last delivery rate on the associated line, whichever is less
  • Bolus Delivery (software version 15.1 and later)
    • 1 to 99.9 mL/hr (in 0.1 mL increments)
    • 100 to 999 mL/hr (in 1 mL increments)
  • Maximum Programmable Duration: 1500:00 hh:mm
Air-in-Line Alarm
  • PlumSet (Distal): Air Bolus at 0.1 mL or larger; Cumulative 0.25 mL out of 4.9 mL
  • PlumSet (Proximal): Air Bolus at 0.5 mL; Cumulative 1.0 mL
Delivery Accuracy
  • 0.1 to 0.9 mL/hr (in 0.1 mL increments): ±10%
  • 1 to 999 mL/hr (in 1 mL increments): ±5%
  • Ambient and Fluid Temperature: 22°C ± 5°C
  • Back Pressure: 0 psi (0 mmHg)
  • I.V. Fluid: Sterile water
  • Filling Head Height: 12” to 24” (30.5 to 61 cm)

Hospira Plum 360

Dimensions
  • Height: 8” (20 cm)
  • Width: 8” (20 cm)
  • Depth: 6” (15 cm)
  • Weight: 10 lbs (4.5 kg)
Battery
  • Type: Sealed lead-acid rechargeable 6V internal battery.
  • Operating Time: About 7 hours when infusing at 25mL/hr and 4 hours at 999 mL/hr.
  • Recharge Time: Up to 8 hours with device operating at 125 mL/hr on one line.
VTBI Range
  • 0.1 to 99.9 mL (in 0.1 mL increments)
  • 100 to 9999 mL (in 1 mL increments)
Delivery Rate Range and Duration
  • Lines A and B: 0.1 to 99.9 mL/hr (in 0.1 mL increments)
  • 100 to 999 mL/hr (in 1 mL increments)
  • Concurrent Delivery: 0.5 mL/hr minimum for each line
  • PlumSet: 500 mL/hr cumulative (A+B) maximum
  • KVO: 1.0 mL/hr or the last delivery rate on the associated line, whichever is less
  • Bolus Delivery (software version 15.1 and later)
    • 1 to 99.9 mL/hr (in 0.1 mL increments)
    • 100 to 999 mL/hr (in 1 mL increments)
  • Maximum Programmable Duration: 1500:00 hh:mm
Air-in-Line Alarm
  • PlumSet (Distal): Air Bolus at 0.1 mL or larger; Cumulative 0.25 mL out of 4.9 mL
  • PlumSet (Proximal): Air Bolus at 0.5 mL; Cumulative 1.0 mL
Delivery Accuracy
  • 0.1 to 0.9 mL/hr (in 0.1 mL increments): ±10%
  • 1 to 999 mL/hr (in 1 mL increments): ±5%
  • Ambient and Fluid Temperature: 22°C ± 5°C
  • Back Pressure: 0 psi (0 mmHg)
  • I.V. Fluid: Sterile water
  • Filling Head Height: 12” to 24” (30.5 to 61 cm)

Related Keyphrase:

  • Hospira Plum 360 Infusion Pump
  • hospira plum 360 price

Download the operator’s Manual

https://web.facebook.com/infusionpumprepair/photos/a.101426038761773/102809741956736