The Medtronic Kangaroo® Feeding Pump is a rotary peristaltic pump designed to regulate the flow rate of enteral feedings.

Features
  • Portable operation-built in battery
  • Wide flow rate range
  • 1-5 ml/hr in 1ml/hr increments
  • 50-300 ml/hr in 5 ml/hr increments
  • Small and lightweight for easy transport
  • Touch panel operation
  • Shut off and activation of audible and visible alarms when:
  • -feeding container is empty
  • -feeding tube becomes occluded
  • -drop sensors blocked
  • -battery low (alarms 15 minutes before pump shut off)
  • -unit is left on “HOLD” longer than 2 1/2 minutes
  • -pump set is improperly loaded
  • -self diagnosed problem which requires technical servicing
  • -pump motor malfunction
  • Automatic systems check after pump has been turned ON
  • Large LED display
  • Removable power cord
  • Low occlusion pressure. Pump will not overcome back pressure greater than approximately 12psi (82.7kPa)
  • Integral pole clamp
  • Use of safety interlock pump sets to prevent free flow from inadvertent misload of pump set onto pump
  • Pump running indicator lights
  • DC motor with intermittent operation
  • Adjustable alarm volume
  • Memory of flow rate, dose, and volume delivered settings for 24 hours after pump shut off

phone Call for price: (855) 477-8866

Download the operator's Manual

Description

Kangaroo 324

Here are the specification of Kangaroo 324 Infusion Pump Repair. Download kangaroo 324 feeding pump and kangaroo 324 manual

  • Type Infusion Device Volumetric
  • Pumping Mechanism Rotary Peristalic
  • Pump Set Required Sherwood Medical Kangaroo® Feeding Pump Administration Sets
Operating Range
  • Rate: 1-50 ml/hr in 1 ml/hr increments 50-300 ml/hr in 5 ml/hr increments
  • Dose 5 2000 ml in 5 mi increments
  • Volume Delivered: 1-9999 ml
  • Memory of Settings When Pump is Off 24 hours for all settings
  • Accuracy flow ±10% of selected rate
  • Occlusion Pressure 12 psi (82.7 kPa) Nominal
Alarms
  • Flow Error
  • Low Battery
  • Hold Error
  • No Set
  • System Error
  • Dose Delivered
Battery
  • Rechargeable
  • Automatically charges when pump is plugged into wall outlet. Recharge time for fully discharged battery is approximately 15 hours.
  • A new battery, when fully charged, will operate for approximately 24 hours at 125 milliliters per hour.

Dimensions Approximately 7.25″ High x 5.5″ Wide x 4.25″ Deep

Weight Approximately 3.625 Ibs.

Case Material ABS Plastic -FIRE RESISTANT

Power Requirements 120V, 60 Hz, 1 Amp

description :

The kangaroo 324 pump is a rotary peristaltic pump designed to regulate the flow rate of enteral feedings

Features
  • Portable operation-built in battery
  • Wide flow rate range
  • 1-5 ml/hr in 1ml/hr increments
  • 50-300 ml/hr in 5 ml/hr increments
  • Small and lightweight for easy transport
  • Touch panel operation
  • Shut off and activation of audible and visible alarms when:
  • -feeding container is empty
  • -feeding tube becomes occluded
  • -drop sensors blocked
  • -battery low (alarms 15 minutes before pump shut off)
  • -unit is left on “HOLD” longer than 2 1/2 minutes
  • -pump set is improperly loaded
  • -self diagnosed problem which requires technical servicing
  • -pump motor malfunction
  • Automatic systems check after pump has been turned ON
  • Large LED display
  • Removable power cord
  • Low occlusion pressure. Pump will not overcome back pressure greater than approximately 12psi (82.7kPa)
  • Integral pole clamp
  • Use of safety interlock pump sets to prevent free flow from inadvertent misload of pump set onto pump
  • Pump running indicator lights
  • DC motor with intermittent operation
  • Adjustable alarm volume
  • Memory of flow rate, dose, and volume delivered settings for 24 hours after pump shut off

Related Keyphrase:

  • Kangaroo 324 Infusion Pump
  • kangaroo 324 manual

Download the operator’s Manual

https://web.facebook.com/infusionpumprepair/photos/a.101426038761773/102159708688406